home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 14421gar.txt < prev    next >
Text File  |  1998-06-22  |  39KB  |  830 lines

  1.                          SECTION 14421
  2.  
  3.                         WHEELCHAIR LIFTS
  4. NOTE ** This section is based on inclined wheelchair
  5.         platform lifts manufactured by Garaventa, located
  6.         at:
  7. NOTE **      7505 - 134A Street     US Mailing Address:
  8. NOTE **      Surrey, BC                PO Box 1769
  9. NOTE **      Canada V3W 7B3            Blaine, WA  98231-
  10.         1769
  11. NOTE **      Tel:  (604) 594-0422 or (800) 663-6556
  12. NOTE **      Fax:  (604) 594-9915
  13. NOTE **      E-mail:  bbell@garaventa.com
  14.  
  15. NOTE ** The section includes interior electrically operated
  16.         lifts running on tubular guide rails along standard
  17.         stairways serving two landings with two stops.
  18.         Ramps may be manually or electrically operated,
  19.         with optional safety arms.  Also included are self-
  20.         contained emergency evacuation chairs for providing
  21.         means of egress for persons unable to walk down
  22.         stairs.  Garaventa also manufactures wheelchair
  23.         lifts for outdoor applications and wheelchair lifts
  24.         serving more than two landings; see their Section
  25.         14420.
  26. NOTE **
  27. NOTE ** SECTION 14421 - WHEELCHAIR LIFTS, Copyright 1998,
  28.         The Architect's Catalog, Inc.
  29.  
  30. PART 1  GENERAL
  31.  
  32. 1.1 SECTION INCLUDES
  33. NOTE ** This section is organized to produce a
  34.         specification for a single type of lift and one of
  35.         3 basic platform types.  If more than one type is
  36.         required, it will be necessary to prepare more than
  37.         one version of this section or edit the section to
  38.         indicate which features apply to which lift.  It
  39.         may also be desirable to indicate which basic type
  40.         each lift is in the list below.
  41.  
  42.     A.  Inclined wheelchair platform lifts for interior
  43.         installation, including:
  44.         1.  Driving machine housed in a locked cabinet.
  45.         2.  Platform.
  46.         3.  Guide rails.
  47.         4.  Control system, signals, electrical wiring, and
  48.             devices necessary to provide specified or code-
  49.             required performance, operation, safety, and security
  50.             to complete lift assembly.
  51. NOTE ** Delete items not required for project.  Add items
  52.         as required.  A support tower might not be needed
  53.         if the structure can carry the weight of the lift
  54.         directly.  Handrails can be provided by the lift
  55.         manufacturer if desired.
  56.         5.  Support towers.
  57.         6.  Handrails and infill panels.
  58.  
  59.     B.  Emergency Evacuation Chairs.
  60.  
  61.     C.  Products Furnished but Not Installed:
  62.         1.  Sleeves, inserts and anchoring devices required for
  63.             the attachment to substrate surfaces.
  64.  
  65. 1.2 RELATED SECTIONS
  66.  
  67.     A.  Division 16 - Electrical service to each lift drive
  68.         cabinet, including fused disconnect switch.
  69.         1.  Power supply of 208 or 240 volt AC, single phase.
  70.         2.  Control voltage circuit breaker rating 20 amps.
  71.  
  72. 1.3 REFERENCES
  73. NOTE ** Delete references from the list below that are not
  74.         actually required by the text of the edited
  75.         section.
  76.  
  77.     A.  ADAAG - Americans with Disabilities Act, Accessibility
  78.         Guidelines.
  79.  
  80.     B.  ANSI A117.1 - Providing Accessibility and Usability for
  81.         Physically Handicapped People.
  82.  
  83.     C.  ASME/ANSI A17.1 - Safety Code for Elevators and
  84.         Escalators.
  85.  
  86.     D.  ASTM A 312 - Standard Specification for Seamless and
  87.         Welded Austenitic Stainless Steel Pipe.
  88.  
  89.     E.  CAN/CSA-B355-M92 - Lifts for Persons with Physical
  90.         Disabilities.
  91.  
  92.     F.  NFPA 70 - National Electrical Code.
  93.  
  94. 1.4 SUBMITTALS
  95.  
  96.     A.  Product Data:  Submit manufacturer's product data and
  97.         installation instructions for the type of wheelchair lift
  98.         system required.  Include the following:
  99.         1.  Each item, accessory and option required.
  100.         2.  Equipment capacity, performance, operation and
  101.             finishes.
  102.         3.  Controls, safety features and similar information.
  103.         4.  Drive system and components.
  104.  
  105.     B.  Shop Drawings:  Submit shop drawings for the type of
  106.         wheelchair lift system required.  Show the following:
  107.         1.  Dimensioned drawings including plans, elevations and
  108.             sections to show equipment locations, interfaces with
  109.             stairway and adjacent substrates, landings served and
  110.             travel distances.
  111.         2.  Details of assembly, erection, anchorage and
  112.             clearance requirements.
  113.         3.  Loads imposed on building structure at points of
  114.             support and other similar considerations for the
  115.             installation of the lift.
  116.  
  117.     C.  Samples for Color Selection:  Submit manufacturer's color
  118.         charts showing full range of available colors and
  119.         finishes for initial color and finish selection of
  120.         exposed materials.
  121.  
  122.     D.  Samples for Verification:  When requested, submit samples
  123.         for verification of selected material colors and finishes
  124.         for platforms, guide-rails, drive cabinets, signal
  125.         devices and control stations.
  126.  
  127.     E.  Certificates and Permits:  Submit inspection/acceptance
  128.         certificates and operating permits required by governing
  129.         authorities to allow normal unrestricted use of
  130.         wheelchair lifts.
  131.  
  132.     F.  Operation and Maintenance Manuals:  Submit bound manuals
  133.         for the type of wheelchair lift required, with operating
  134.         and maintenance instructions, parts listing with sources
  135.         indicated, recommended parts inventory listing, emergency
  136.         instructions, warranty duration and similar information.
  137.  
  138.     G.  Warranty:  Submit manufacturer's standard wheelchair lift
  139.         warranty.
  140.  
  141. 1.5 QUALITY ASSURANCE
  142.  
  143.     A.  Manufacturers Qualifications:  A company with not less
  144.         than twenty (20) years of experience in the design,
  145.         fabrication, installation and maintenance of inclined
  146.         platform lifts of the type, quality and character
  147.         required.
  148. NOTE ** If the following requirement is important, insert
  149.         the maximum distance in the blank.
  150.         1.  Manufacturer shall have a service office and
  151.             warehouse of parts within a ______ mile radius of
  152.             project site.
  153.  
  154.     B.  Installer Qualifications:  The lift manufacturer or a
  155.         qualified, authorized agent of the lift manufacturer with
  156.         not less than ten (10) years of experience installing and
  157.         servicing inclined wheelchair platform lifts of the type
  158.         required.
  159.  
  160.     C.  Design Requirements:  Wheelchair lift systems shall be
  161.         certified by a licensed Professional Engineer experienced
  162.         in the design of inclined wheelchair platform lifts in
  163.         accordance with applicable codes.
  164.  
  165.     D.  Regulatory Requirements:  Materials and construction
  166.         shall comply with the current edition of the following
  167.         codes, standards and guidelines.
  168. NOTE ** Delete any of the following regulations that do not
  169.         apply to this project. If necessary, verify current
  170.         edition date.
  171.         1.  ASME/ANSI A17.1 "Safety Code for Elevators and
  172.             Escalators", Part XX (Commercial and Public
  173.             Buildings).
  174.         2.  CAN/CSA-B355-M92 "Lifts for Persons with Physical
  175.             Disabilities."
  176.         3.  ANSI A117.1,  "Providing Accessibility and Usability
  177.             for Physically Handicapped People."
  178.         4.  NFPA No 70,  National Electric Code.
  179.         5.  ADAAG Americans with Disabilities Act Accessibility
  180.             Guidelines.
  181.         6.  Provide CSA or UL tested and labeled mechanical and
  182.             electrical equipment.
  183. NOTE ** If the local building code contains additional
  184.         requirements relating to wheelchair lifts, enter
  185.         the name of the local building code in the blank.
  186.         7.  ___________________ Building Code.
  187.  
  188. 1.6 DELIVERY, STORAGE AND HANDLING
  189.  
  190.     A.  Provide wheelchair lift materials, components and
  191.         equipment wrapped, boxed, or crated to protect factory
  192.         finishes.
  193.  
  194.     B.  Deliver, store, protect and handle wheelchair lift
  195.         materials and components in accordance with the
  196.         manufacturer's recommendations to prevent damage, soiling
  197.         or deterioration.
  198.  
  199. 1.7 PROJECT CONDITIONS
  200.  
  201.     A.  Field verify installation dimensions and conditions. Show
  202.         modifications required to accommodate the required
  203.         wheelchair lift on shop drawings.
  204.  
  205.     B.  Arrange for required inspections and tests.  Obtain
  206.         inspection/acceptance certificates and initial operating
  207.         permits required by local governing authorities and turn
  208.         over to the Owner upon acceptance of the work.
  209. NOTE ** Delete one of the following 2 paragraphs.
  210.         1.  Costs of inspections, tests and permits will be paid
  211.             for by Owner.
  212.         2.  Costs of inspections, tests and permits will be paid
  213.             for by installer.
  214.  
  215. 1.8 WARRANTY
  216.  
  217.     A.  Warranty:  Manufacturer shall warrant the wheelchair lift
  218.         materials and workmanship for one year following
  219.         completion of the installation.  Warranty shall include
  220.         replacement of defective parts not due to ordinary wear
  221.         during use or improper use.
  222. NOTE ** Extended warranty is available for 3-year and 5-
  223.         year periods, provided the maintenance agreement
  224.         specified below is also included for the same time
  225.         period.  Edit the time period if less than 5 years.
  226.         Delete extended warranty if not required.
  227.         Maintenance agreement may be included even if
  228.         extended warranty is not.
  229.  
  230.     B.  Extended Warranty:  Manufacturer shall warrant the
  231.         wheelchair lift materials and workmanship for five years
  232.         following completion of the installation and execution of
  233.         a preventative maintenance program agreement for five
  234.         years.  Warranty shall include replacement of defective
  235.         parts not due to ordinary wear during use or improper
  236.         use.
  237.  
  238. 1.9 OWNER'S INSTRUCTIONS
  239.  
  240.     A.  Upon completion of the installation, instruct Owner's
  241.         designated personnel in the proper use, operation and
  242.         daily maintenance requirements of wheelchair lifts.
  243.         Review emergency provisions, including access and
  244.         provisions to be followed in operation or other building
  245.         emergency conditions.  Train Owner's personnel in
  246.         procedures to follow in identifying sources of
  247.         operational failures or malfunctions.
  248.  
  249.     B.  Coordinate preventative maintenance program service
  250.         schedule and requirements with Owner's designated
  251.         personnel.
  252.  
  253. 1.10    MAINTENANCE
  254. NOTE ** Delete this article entirely if maintenance service
  255.         is not included in the Contract Sum.  This service
  256.         can be contracted separately.  Coordinate with
  257.         requirements for extended warranty above.
  258.  
  259.     A.  Preventative Maintenance Program:  Provide preventative
  260.         maintenance of wheelchair lift units.  Maintenance
  261.         service shall be carried out not less than every six
  262.         months.  Correct operational imperfections and restore or
  263.         replace defective or deteriorated components and
  264.         finishes.  Use only genuine parts, components, and
  265.         supplies as used in the manufacture and installation of
  266.         original equipment.
  267. NOTE ** Delete all but one of the following 3 paragraphs.
  268.         Coordinate maintenance period with requirements for
  269.         extended warranty above (maintenance period and
  270.         warranty period should match).  Edit maintenance
  271.         period if required.
  272.         1.  Maintenance program period:  12 months following
  273.             completion of the installation.
  274.         2.  Maintenance program period:  36 months following
  275.             completion of the installation.
  276.         3.  Maintenance program period:  60 months following
  277.             completion of the installation.
  278.         4.  Include the following services:
  279.             a.  Clean and lubricate as required.  Supply required
  280.                 lubricants and touch-up paint.
  281.             b.  Check electrical and mechanical operation and
  282.                 make minor adjustments as necessary.
  283.             c.  Recommend repairs or replacement of parts needed
  284.                 to ensure reliable operation.
  285.             d.  Test operation and safety systems.
  286.             e.  Other services as required.
  287.         5.  Provide regular and 24 hour emergency callback
  288.             service as part of the maintenance service.
  289.  
  290.     B.  Maintenance service shall be performed solely by the
  291.         manufacturer or an authorized manufacturer's
  292.         representative and shall not be assigned or transferred
  293.         to any other agent, party or subcontractor.
  294.  
  295.  
  296. PART 2  PRODUCTS
  297.  
  298. 2.1 MANUFACTURERS
  299.  
  300.     A.  Provide products manufactured by Garaventa, P.O. Box
  301.         1769, Blaine WA 98231-1769; or 7505-134A Street, Surrey,
  302.         BC V3W7B3; ASD. Tel: (800) 663-6556 or (604) 594-0422,
  303.         Fax: (604) 594-9915, E-mail: bbell@garaventa.com.
  304.  
  305. 2.2 WHEELCHAIR LIFTS
  306.  
  307.     A.  General:  Provide manufacturer's standard pre-engineered
  308.         lift system that complies with specified requirements.
  309.         Provide Garaventa Stair-Lift products as indicated in
  310.         Garaventa "Design and Planning Guide" and as specified
  311.         for complete inclined stairway wheelchair lift systems.
  312.  
  313.     B.  Wheelchair Lift:  Garaventa Stair-Lift Model GSL-2:
  314.         1.  Configuration:  An inclined wheelchair platform lift
  315.             that travels on square rails along the edge of
  316.             stairways.
  317.         2.  Operation:  Independent or attendant operation, keyed
  318.             controlled constant pressure switches at platform
  319.             controls and landing call stations.
  320.         3.  Rated load:  495 lbs (225 kg); limited to one person,
  321.             with minimum five times safety factor.
  322.         4.  Rated speed:  20 ft (6 meters) per minute.
  323.         5.  Number of Stops:  2.
  324.  
  325. NOTE ** Maximum incline is 40 degrees, measured on the
  326.         mean.  Delete one of the following 2 paragraphs.
  327.         If the incline is to be specified, enter the angle
  328.         in the blank.
  329.         6.  Incline:  As indicated on drawings.
  330.         7.  Incline:  ______ degrees.
  331. NOTE ** Delete one of the following 2 paragraphs.  Verify
  332.         that electrical power characteristics required by
  333.         manufacturer are compatible with building power
  334.         supply and coordinate with power supply specified
  335.         under Related Sections.
  336.         8.  Power supply:  208 volt AC, single phase, 60 hertz.
  337.         9.  Power supply:  240 volt AC, single phase, 60 hertz.
  338.         10. Operating controls voltage:  24 volt DC.
  339. NOTE ** Delete all but one of the following 3 platform
  340.         types.  Type S has manually operated ramps.  Type
  341.         SP and SPC have electrically operated ramps and
  342.         folding platform.  In addition, Type SPC has
  343.         electrically operated safety arms.  Type S can be
  344.         upgraded to SP after installation; SP be upgraded
  345.         to SPC.
  346.  
  347.     C.  Platform:  "Type S"; manual folding and unfolding
  348.         platform and loading ramps.
  349.  
  350.     D.  Platform:  "Type SP"; electrically operated folding and
  351.         unfolding platform and ramps.
  352.  
  353.     E.  Platform:  "Type SPC"; electrically operated folding and
  354.         unfolding platform, ramps and safety arms.
  355. NOTE ** Delete one of the following 2 paragraphs.  Custom
  356.         widths and longer ramps are available.  Insert
  357.         dimensions in blank.
  358.         1.  Width:  30 inches (760 mm).
  359.         2.  Width:  __________________.
  360.         3.  Platform length:
  361. NOTE ** Delete all but one of the following 3 paragraphs.
  362.         The first (1220) is the minimum US-ADA dimension.
  363.             a.  1220 Platform:  48 inches (1220 mm).
  364.             b.  1050 Platform:  41 inches (1050 mm).
  365.             c.  900 Platform:  35.4 inches (900 mm).
  366.         4.  Provide non-slip platform deck and ramp surfaces.
  367.         5.  Ramps:  Provide loading ramps 6 inches (150 mm) high,
  368.             when folded, to prevent accidental wheelchair roll-
  369.             off.
  370.             a.  Loading ramps shall be mechanically and
  371.                 electrically interlocked during travel, to
  372.                 prevent lift travel unless ramps are raised and
  373.                 to prevent lowering ramps during lift travel.
  374. NOTE ** Delete the following 2 paragraphs for Type S.
  375.         Retain the first paragraph for Type SP, the second
  376.         for Type SPC.
  377.             b.  Ramps:  Loading ramps raised and lowered
  378.                 electrically, only when platform is unfolded and
  379.                 at rest at a landing.
  380.             c.  Ramps:  Loading ramps raised and lowered
  381.                 electrically, operated in sequence with the
  382.                 correct safety arm, only when the platform is
  383.                 unfolded and at rest at a landing.
  384. NOTE ** Delete the following paragraph if side-loading
  385.         platform is not required.  Side-loading platform is
  386.         often required when landing clearances are limited.
  387.         Delete for Type S platform.
  388.             d.  Side-load platform:  Provide 6 inch (150 mm) high
  389.                 side loading ramp for passenger loading access
  390.                 from virtually any direction.  Sideload ramp
  391.                 motor shall not be mounted on platform surface
  392.                 area.
  393.         6.  Kick-plate:  6 inches (150 mm) high, functions as
  394.             vandal resistant cover to protect platform control
  395.             switches when in folded position.
  396. NOTE ** The following safety arms are optional on Type S
  397.         and SP platforms.  Delete if not desired, or if
  398.         Type SPC is used.
  399.         7.  Safety arms:  "Bar-Guard" manually operated safety
  400.             arms at each end of the platform.
  401. NOTE ** Delete the following paragraph for Type S and SP
  402.         platform - standard on SPC.
  403.         8.  Safety arms:  Provide electrically operated safety
  404.             arms at each end of the platform.
  405. NOTE ** The following grab rails are optional on Type S and
  406.         SP platforms; delete if not desired.
  407.         9.  Grab-rails:  Provide passenger grab-rail installed on
  408.             the platform.
  409.         10. Clearances - direct mounted:  The folded platform
  410.             shall not protrude more than 13.5 inches (341 mm)
  411.             from inner wall.  (Variations may apply when
  412.             technically infeasible).  When unfolded and in use,
  413.             platform shall not protrude more than 39.5 inches
  414.             (1005 mm) from inner wall.
  415.         11. Carriages:  Provide upper and lower carriages for
  416.             supporting the platform on the guide-rails and
  417.             guiding the platform up and down the guide-rail tube
  418.             system.
  419.         12. Platform operation:
  420.             a.  A smooth start/stop shall be provided when
  421.                 entering/departing landing zone.
  422.             b.  Platform shall negotiate vertical and horizontal
  423.                 bends and transitions smoothly with one unit,
  424.                 without transfer.
  425.             c.  Platform carriages shall be equipped with nylon
  426.                 rollers that permit the carriage to run smoothly
  427.                 on the guide-rail.
  428.         13. Platform travel safeties:  Stop the lift when
  429.             travelling in folded or unfolded position and an
  430.             obstruction causing four pounds or more pressure is
  431.             met.  Provide the following sensing devices:
  432.             a.  Under-platform touch-sensitive plate.
  433.             b.  Under-hanger touch-sensitive plate.
  434.             c.  Multi-directional touch-sensitive ramps.
  435.         14. Platform parking:  When the lift is not being used,
  436.             the platform shall be parked in the folded position
  437.             away from the stairway at the lower landing.
  438. NOTE ** The following paragraph covers a non-standard
  439.         option for Type S platform.  Delete if not desired.
  440.         15. Security platform lock:  Manual security lock
  441.             utilizing operation key provided by the manufacturer
  442.             to prevent unauthorized unfolding of platform.
  443. NOTE ** The following paragraph covers a non-standard
  444.         option for Type SP and SPC platforms.  Delete if
  445.         not required, or if Type S is used.
  446.         16. Security platform lock:  Solenoid security lock
  447.             operated from the call station to prevent
  448.             unauthorized unfolding of platform.  Automatically
  449.             unlocks platform when unfolding platform from the
  450.             call station.
  451. NOTE ** The following 3 paragraphs cover options not
  452.         standard.  Delete if not desired.
  453.         17. Fold-down seat:  Manual fold-down seat complete with
  454.             armrests and safety belt mounted upon the platform.
  455.         18. Platform light:  Deck light platform area
  456.             illumination.  An integral lamp which activates
  457.             automatically when the platform is in the unfolded
  458.             position.  Provided in combination with the fold-down
  459.             seat.
  460.         19. Platform storage:  Platform shall be able to be
  461.             stored in the "park beyond" position at the upper
  462.             landing.
  463.  
  464. 2.3 OPERATING CONTROLS AND SIGNALS
  465.  
  466.     A.  Control System:  Provide key-operated switch at each
  467.         control station that permits "up" and "down" switches to
  468.         become effective only when the key is in the "on"
  469.         position.  Controls shall comply with requirements of
  470.         ANSI A117.1 and ASME/ANSI A17.1.
  471.         1.  Platform controls:
  472.             a.  Key switch, constant pressure directional paddle
  473.                 switch, emergency stop button, and plug-in
  474.                 extension control for attendant or passenger
  475.                 operation.
  476.             b.  Safe-to-go Ready Lamp indicating safety circuits
  477.                 are clear and lift is ready to operate.
  478.         2.  Call station controls:  Provide at each landing:
  479. NOTE ** Delete all but one of the Upper Landing paragraphs,
  480.         and all but one of the Lower Landing paragraphs.
  481.             a.  Upper landing:  Mounted on tubular guide-rails
  482.                 adjacent to Drive Cabinet.
  483.             b.  Upper landing:  Wall mounted.
  484.             c.  Upper landing:  Tower mounted.
  485.             d.  Upper landing:  Mounted on Drive Cabinet.
  486.             e.  Lower landing:  Wall mounted in surface-mounted
  487.                 fitting as indicated.
  488.             f.  Lower landing:  Wall mounted in recessed flush-
  489.                 mount fitting as indicated.
  490.             g.  Lower landing:  Free-standing as indicated.
  491.             h.  "Power-on" lamp, key switch, "station-activated"
  492.                 lamp, "fault" lamp, constant pressure platform
  493.                 call/send paddle switch, "lift-location" lamp.
  494. NOTE ** Delete the following 2 paragraphs if Type S
  495.         platform is used.  Retain first paragraph for Type
  496.         SP and second paragraph for Type SPC.
  497.             i.  Constant pressure switch to fold and unfold the
  498.                 platform and to operate loading ramps.
  499.             j.  Constant pressure switch to fold and unfold the
  500.                 platform and to operate the loading ramps and
  501.                 safety arms.
  502. NOTE ** Delete the following call station options if not
  503.         required.
  504.         3.  Call station control options:
  505.             a.  Constant pressure attendant call switch in call
  506.                 station.
  507.             b.  Constant pressure emergency stop switch in call
  508.                 station.
  509.         4.  Attendant operation:  Provide manufacturer's standard
  510.             plug-in, hand-held attendant control unit with each
  511.             wheelchair lift required.
  512.             a.  Key switch, constant pressure directional paddle
  513.                 switch and emergency stop button.
  514.             b.  Provide a removable lockout cover on the platform
  515.                 control station directional paddle switch when
  516.                 required by local governing authorities.
  517.         5.  Leveling tolerance:  Provide terminal stopping system
  518.             at each extreme of travel and adjust to maintain
  519.             level tolerance within 1/2 inch (13 mm) regardless of
  520.             load size or direction of travel.
  521.         6.  Limit switches:  Provide at both top and bottom
  522.             extremes of travel.
  523.         7.  Obstruction sensors:  Provide sensors to cut power
  524.             and stop unit in the event of contact with foreign
  525.             object within pathway of travel.  Comply with
  526.             applicable codes.
  527.         8.  Safety device:  Provide safety device to stop
  528.             platform in event of overspeed condition or breakage
  529.             or slackening of suspension of support means.
  530.         9.  Manual lowering:  Provide means to manually lower
  531.             platform in case of malfunction or power loss.
  532.         10. Manual folding:  Provide means to manually fold
  533.             platform in case of malfunction or power loss.
  534. NOTE ** Delete any of the following safety options not
  535.         required.  The AV option may be required by local
  536.         building authorities; the LEA and ERA options
  537.         comply with ANSI A17.1, Rule 2000.11.
  538.  
  539.     B.  Safety Signal Options:
  540.         1.  Audio-Visual Alert (AV):  Provide wall-mounted Audio-
  541.             Visual Pedestrian Alert devices within designated
  542.             stairways to alert stairway pedestrians that the
  543.             wheelchair lift is being operated.  Device shall
  544.             contain a tri-octave audio chime and flashing amber
  545.             strobe which is activated when the platform is in
  546.             motion or unfolded in a stationary position.
  547.         2.  Local Emergency Alarm (LEA):  Provide an emergency
  548.             alarm system from the platform for emergency
  549.             assistance for the passenger.  Pressing the platform
  550.             control emergency stop button shall sound an audible
  551.             signal in the vicinity of the drive box and at a
  552.             receiver console.  Include backup battery operation
  553.             to ensure help is summoned in a power outage.
  554.         3.  Emergency Remote Alarm (ERA) - radio transmitted:
  555.             Provide an emergency remote alarm system from the
  556.             platform for emergency assistance for the passenger.
  557.             Pressing the platform control emergency stop button
  558.             shall transmit a signal to a receiver console, which
  559.             shall provide an audible alarm and a visible light
  560.             indicator that help is needed.  Include backup
  561.             battery operation to ensure help is summoned in a
  562.             power outage.
  563. NOTE ** Delete one of the following 2 paragraphs.  If
  564.         known, enter the location of the receiver console
  565.         in the blank.
  566.             a.  Locate receiver console where indicated.
  567.             b.  Locate receiver console at _____________.
  568.  
  569.     C.  Fire Service Controls:  Provide fire service to ensure
  570.         lift is not used for emergency egress and does not impede
  571.         emergency egress stairway traffic.
  572.         1.  When fire alarm is activated, lift shall not operate
  573.             if platform is folded and key is turned off.
  574.         2.  If the lift is in use when fire alarm is activated,
  575.             the lift shall travel only in one direction - towards
  576.             the landing that is designated as the emergency exit.
  577.  
  578. 2.4 DRIVE SYSTEM
  579.  
  580.     A.  Drive System Components:  Provide wheelchair drive system
  581.         components, including the motor, gearbox and controller,
  582.         contained within a locked drive system cabinet.
  583.         1.  Drive system cabinet:  Steel cabinet, 63 inches (1600
  584.             mm) high by 11 inches (280 mm) wide by 7.9 inches
  585.             (200 mm) deep.  Located at the top landing of the
  586.             wheelchair lift system; locked to prevent
  587.             unauthorized access.
  588.         2.  Drive system motor:  1 HP/200/240 volts AC.
  589.             a.  Fit motor with an electrically released spring-
  590.                 set brake to stop automatically at landings.
  591.         3.  Provide handwheel for emergency drive system
  592.             operation during power failure.
  593.         4.  Gearbox:  Drive system features a toothed belt drive
  594.             from the motor to a sealed lubrication gearbox with
  595.             64:1 reduction.  The gearbox output shaft drives the
  596.             cog which engages the roller chain.
  597.         5.  Power supply:  As indicated above.  Locate disconnect
  598.             and thermal overload device on the side of the drive
  599.             cabinet.
  600.  
  601. 2.5 RAIL SYSTEM
  602. NOTE ** Select support tower from the following two
  603.         paragraphs; delete both paragraphs if support tower
  604.         not required.
  605.  
  606.     A.  Support Tower:  Structural steel, self-supporting, free-
  607.         standing support structure.
  608.  
  609.     B.  Support Tower:  Stainless steel, self-supporting, free-
  610.         standing support structure.
  611. NOTE ** Verify structural conditions for tower.  The
  612.         following description is fairly normal for an
  613.         existing structure, but does have structural
  614.         impact.
  615.         1.  Provide tower framing that requires vertical-load
  616.             support only at base and lateral support only at
  617.             landing levels.
  618.  
  619.     C.  Guide-Rails:  Three 2-1/2 inch (65 mm) square tubular
  620.         steel rails.
  621.         1.  Tubes shall run along edge of stair flights and
  622.             horizontal landings throughout the length of travel.
  623.         2.  Provide direct mount vertical steel distance struts,
  624.             spaced as required, to maintain vertical separation
  625.             distance of guide-rail tubes.  Weld guide-rails to
  626.             distance struts.
  627. NOTE ** The following three paragraphs cover handrails that
  628.         are optional.  Coordinate with other construction
  629.         and with stair railings specified elsewhere.
  630.  
  631.     D.  Handrails:  Provide additional handrails in compliance
  632.         with code at the standard handrail height for pedestrian
  633.         use, in same plane as guide-rail tubes.  Match material
  634.         and finish of guide-rail tube.
  635.  
  636.     E.  Matching Handrails:  Provide matching handrails at
  637.         opposite side of stairway and for other areas of the
  638.         building where indicated.  Match material and finish of
  639.         guide-rail tube.
  640.  
  641.     F.  Infill panels:  Provide infill panels at locations
  642.         indicated.
  643. NOTE ** Delete all but one of the following panel
  644.         descriptions.
  645.         1.  Panels:  Woven wire mesh, 2 inch (50 mm) square,
  646.             welded to a 1 inch (25 mm) angle frame.  Painted
  647.             finish matching guide-rail system.
  648.         2.  Panels:   Design indicated, painted finish matching
  649.             guide-rail system.
  650.         3.  Panels:   _________________________
  651.  
  652. 2.6 FINISHES
  653. NOTE ** Baked powder coating is standard.  Zinc-plated and
  654.         stainless steel finishes are optional and would be
  655.         used for exterior installations.
  656.  
  657.     A.  All Exposed Steel Members:  Electrostatically applied
  658.         baked powder coating.
  659.  
  660.     B.  All Exposed Steel Members:  Electrostatically applied
  661.         baked powder coating paint finish, unless otherwise
  662.         indicated.
  663. NOTE ** Delete all but one of the following seven color
  664.         paragraphs.  Consult manufacturer on availability
  665.         of custom colors.
  666.         1.  Color:  As selected by the Architect from
  667.             manufacturer's full range, standard and non-standard.
  668.         2.  Color:  Custom color to be selected from Garaventa.
  669. NOTE ** The first two colors in the following paragraphs
  670.         are standard; the next three are optional colors.
  671.         3.  Color:  Cool Grey.
  672.         4.  Color:  Sahara Sand.
  673.         5.  Color:  Evening Rose.
  674.         6.  Color:  Teal Green.
  675.         7.  Color:  Pacific Blue.
  676. NOTE ** Use the following paragraph if all components are
  677.         to be stainless steel.  Delete if standard baked
  678.         enamel finish is acceptable, or if only certain
  679.         components are to be stainless steel.
  680.  
  681.     C.  All Exposed Steel Members:  Electro-polished finish
  682.         stainless steel.
  683. NOTE ** Use the following paragraph if only certain
  684.         components are to be stainless steel, with the
  685.         remainder either baked enamel or zinc-coated.  The
  686.         following components can be stainless for an
  687.         exterior installation.
  688.  
  689.     D.  Stainless Steel Finish:  Electro-polished; use for the
  690.         following components:
  691. NOTE ** Delete any components not applicable.  Add others
  692.         as required.
  693.         1.  Drive cabinet.
  694.         2.  Under-platform touch sensitive plate.
  695.         3.  Guide-rail distance struts.
  696.         4.  Towers.
  697.         5.  Call stations.
  698.         6.  Call station pedestals.
  699.         7.  Audio/visual alert signals.
  700. NOTE ** The following emergency evacuation chairs are not
  701.         part of the wheelchair lift, but provide means of
  702.         egress for people with a disability when the lift
  703.         cannot be used, such as during a fire when
  704.         elevators also cannot be used.  The Garaventa Evacu-
  705.         Trac is a device that allows even a petite
  706.         attendant to safely move a person weighing up to
  707.         360 pounds down stairways.  The chair, designed
  708.         with two long, steel-reinforced rubber tracks, an
  709.         overspeed governor, and a release brake, is
  710.         extremely stable and secure on stairs.  It allows a
  711.         person with a disability to escape the building,
  712.         rather than having to wait to be rescued.
  713.  
  714. 2.7 EMERGENCY EVACUATION CHAIRS
  715.  
  716.     A.  Emergency Evacuation Chairs:  Housed in steel storage
  717.         cabinet located adjacent to each landing floor above
  718.         ground level.  Comply with the following:
  719.         1.  Type:  Garaventa Evacu-Trac.
  720.         2.  Capacity:  1 person, 360 pounds (163 kg) with minimum
  721.             1.5 times safety factor.
  722.         3.  Approval:  Tested and approved by recognized
  723.             independent testing lab.
  724.         4.  Maximum stair angle:  40 degrees.
  725.         5.  Descending speed:  Maximum 4 feet (1.2 m) per second.
  726.         6.  Speed governor:  Piston brake.
  727.         7.  Stop brake:  Manual mechanical brake, attendant must
  728.             release for descent.
  729.         8.  Storage:  Steel cabinet, Plexiglass door panel.
  730.         9.  Cabinet dimensions (approximate):  21.5 inches (545
  731.             mm) wide x 11 inches (275 mm) high x 44.5 inches (275
  732.             mm) deep.
  733.  
  734.  
  735. PART 3  EXECUTION
  736.  
  737. 3.1 EXAMINATION
  738.  
  739.     A.  Before starting wheelchair lift installation, inspect
  740.         substrates and supporting structures as constructed,
  741.         verify critical dimensions, and examine conditions under
  742.         which wheelchair lift work is to be installed.
  743.  
  744.     B.  Do not proceed with wheelchair lift installation until
  745.         unsatisfactory conditions have been corrected in a manner
  746.         acceptable to the installer.
  747.  
  748.     C.  Installation constitutes acceptance of existing
  749.         conditions and responsibility for satisfactory
  750.         performance.
  751.  
  752. 3.2 INSTALLATION
  753.  
  754.     A.  General:  Comply with manufacturer's instructions and
  755.         recommendations for work required during installation.
  756. NOTE ** Delete one of the following 2 paragraphs.
  757.         1.  Comply with requirements of ASME/ANSI A17.1 for
  758.             inclined wheelchair platform lift design, materials,
  759.             methods of construction and installation.
  760.         2.  Comply with requirements of CAN/CSA-B355-M92 for
  761.             inclined wheelchair platform lift design, materials,
  762.             methods of construction and installation.
  763.         3.  Comply with the National Electrical Code for
  764.             electrical work required during installation.
  765.         4.  Perform work with competent, skilled workers under
  766.             the direct control and supervision of the wheelchair
  767.             lift installer's experienced foreman.
  768.  
  769.     B.  Supply in ample time for installation by other trades,
  770.         inserts, anchors, bearing plates, brackets, supports, and
  771.         bracing including all setting templates and diagrams for
  772.         placement.
  773.  
  774.     C.  Coordination:  Coordinate wheelchair lift work with the
  775.         work of other trades, for proper time and sequence to
  776.         avoid construction delays.
  777.  
  778.     D.  Operation:  Install drive machines, guide-rails,
  779.         controls, car operating controls and all equipment and
  780.         accessories to provide a quiet, smoothly operating
  781.         installation, free from side sway, oscillation or
  782.         vibration.
  783.  
  784.     E.  Alignment:  Coordinate platform travel and positioning,
  785.         for accurate alignment and minimum clearance between
  786.         platform and floor level at each stop and landing served.
  787.  
  788.     F.  Leveling:  Adjust stops for accurate leveling at each
  789.         landing, within specified tolerances.
  790.  
  791.     G.  Lubricate operating parts of each lift, including drive
  792.         system mechanisms, guide-rail systems, platform ramps,
  793.         safety devices, and hardware.
  794.  
  795. 3.3 FIELD QUALITY CONTROL
  796.  
  797.     A.  Acceptance Testing:  Upon completion of the wheelchair
  798.         lift installation and before permitting use of lift
  799.         system, perform acceptance tests as required and
  800.         recommended by code and governing authorities.
  801.         1.  Advise Owner and governing agencies in advance of
  802.             dates and times tests are to be performed on the
  803.             wheelchair lift.
  804.  
  805.     B.  Cycle Testing:  Test operate unloaded lift, continuously
  806.         between lowest and highest landings served.  Perform
  807.         complete lift operation cycles, including ramp operation
  808.         from the platform controls and call stations for a
  809.         minimum period of 30 minutes.  Adjust controls, stops and
  810.         other devices for accurate landings and operation of
  811.         system after completion of test.
  812.  
  813.     C.  Make necessary adjustments of operating devices and
  814.         equipment to ensure wheelchair lift operates smoothly and
  815.         accurately.
  816.  
  817. 3.4 CLEANING
  818.  
  819.     A.  Before final acceptance, remove protection from finished
  820.         surfaces and clean surfaces in accordance with
  821.         manufacturer's recommendations for type of material and
  822.         finish provided.
  823.  
  824.     B.  At completion of wheelchair lift work, remove tools,
  825.         equipment, and surplus materials from site.  Clean work
  826.         areas.  Remove trash and debris.
  827.  
  828.  
  829.                          END OF SECTION
  830.